Sony Venice
https://support.cyanview.com/docs/Integrations/Sony/SonyVenice

Supported Models
- Sony Venice 1
- Sony Venice 2
Protocols and Controls
There are two protocols:
- Sony Venice Serial: the typical Sony Venice multicam workflow
- Sony Venice IP: if you're working in S-Log and don't want/need camera control through the RCP paint mode
| Control | Venice IP | Venice Serial |
|---|---|---|
| Exposure (Iris, Gain, Shutter *1, ND filter *2) | ✓ *3 | ✓ *4 |
| White balance (color temperature and tint) | ✓ *5 | ✓ *6 |
| Black balance (R/B and Master) | - | ✓ |
| Advanced shading (Flare, Detail, Matrix, Multi Matrix) | - | ✓ *7 |
| REC (start/stop) | ✓ | ✓ |
| Other controls (Base ISO *8, APR, pattern, horizontal/vertical flip, replay *9, User Keys *10, TC) | ✓ | - |
| Tally | - | ✓ *11 |
| Lens (zoom, focus) *12 | ✓ | - |
| Scene file save/recall | ✓ | ✓ |
- Shutter can be displayed/controlled as angle or speed. ECS is also available.
- ND is presets only.
- Venice IP: gain is expressed in ISO and only affects the SDI output. Base ISO (800 or 3200) affects the ISO range and the (fixed) REC ISO.
- Venice Serial: gain is expressed in dB, in 3 dB steps.
- Color temperature, tint and AWB.
- R/B and color temperature are available in Venice Serial, but not tint (only the color temperature is affected).
- Detail can be changed and toggled on/off. Matrix and Multi Matrix can be changed and toggled.
- Base ISO only in Venice IP.
- To replay, switch to Clips under
Camera > User Keys > Custom. Then underRecord > Replay, you can replay your last clip. - User keys are accessible on the RCP under
Camera > User Keys, in User Keys and Custom. You can only call them; they must be assigned on the camera body underProject > Assignable Button. - Venice Serial: RED tally only, and only when not recording (the REC status is used to display the tally).
- Venice IP: zoom/focus are controlled in speed (position is display only).
Wiring
The camera can be controlled in two modes:
- Sony Venice IP: the camera is controlled over IP (works best for S-Log-based workflows; RCP/paint mode is disabled).
- Sony Venice Serial: the camera is controlled over the remote (8-pin) port, using the camera's RCP paint mode.
Locally (LAN), you can control the camera with just the RCP for IP, or by adding a CI0 for serial. Wirelessly (4G, RF, Wi-Fi), you can control it using a RIO for both IP and serial (Steadicam, robotics, etc.).
Sony Venice IP (LAN)

- The RCP is powered by PoE or a 12V PSU.
- The RCP talks directly to the camera over IP.
This can work through a simple Ethernet switch or a fiber system such as the Ereca CAM Racer.
Sony Venice Serial (LAN)

- The RCP is powered by PoE or a 12V PSU.
- The CI0 or RIO is powered by the camera through the cable (no D-TAP required).
- Cable: CY-CBL-SONY-8P-03 (controls the camera and powers the CI0/RIO; see the Cable Catalog)
This can work through a simple Ethernet switch or a fiber system such as the Ereca CAM Racer.
- Some people prefer to keep the CI0/RIO on the camera side, so there is simply Ethernet between the RCP and the CI0/RIO.
- Others prefer to keep the CI0/RIO on the RCP side and carry the serial signal over the Ereca (pro: a clean setup on the camera side; con: you lose the flexibility of the RIO for external motors, lens control, etc.).
Sony Venice IP (Wireless)

- The RCP is powered by PoE or a 12V PSU and connected to the internet.
- The RIO is powered by D-TAP.
- The RIO is connected to the camera over Ethernet.
- The RCP talks to the RIO over the internet (using 4G, RF, Wi-Fi, etc.).
Video must be transmitted separately over RF; Cyanview only handles the telemetry.
Sony Venice Serial (Wireless)

- The RCP is powered by PoE or a 12V PSU and connected to the internet.
- The RIO is powered by D-TAP.
- The RIO is connected to the camera with a CY-CBL-SONY-8P-03 cable.
- The RCP talks to the RIO over the internet (using 4G, RF, Wi-Fi, etc.).
Video must be transmitted separately over RF; Cyanview only handles the telemetry.
Camera Setup
Venice IP
- Set the IP address and mask under
Technical > Network > Setting:- Set Setting to LAN
- In the LAN submenu:
- Set DHCP to Off
- Set IP Address to the desired camera IP (e.g.
10.192.10.100) - Set Subnet Mask to the desired subnet (e.g.
255.255.0.0)
- Set the username and password under
Technical > Authentication - Under
Technical > Special Configuration, set RM / RCP Paint Con to Off
Venice Serial
- Under
Technical > Special Configuration, set RM / RCP Paint Con to On
RCP Setup
Add a new camera in the RCP configuration UI.
Venice IP
- Enter a custom number, name, etc.
- Select brand: Sony
- Select protocol: Sony Venice(IP)
- Enter the camera's IP address
- Enter the camera's login/password


Venice Serial
- Enter a custom number, name, etc.
- Select brand: Sony
- Select protocol: Sony Venice(Serial)
- Select the CI0/RIO port the camera is plugged into


RCP Operation
Overview
The exposure knob and joystick give access to iris, ISO and shutter.
Assignable Keys
You can customize the 10 buttons at the top of the RCP main screen under MENU > SYSTEM > ASSIGN. > Set Buttons. By default, keys 1-5 are not assigned (NA). You can assign them to something more useful, for example:
This gives you quick access to:
-
The Lock button becomes a shortcut to the REC menus (replay, etc.), and its LED reflects the REC status.
-
The camera's assignable buttons (1-4, A-C, Home and Clips)
-
Base ISO from the gain view
-
Shutter angle/speed from the shutter view
-
Test patterns from the test view
Encoders
You can customize the 4 encoders below the RCP main screen under MENU > SYSTEM > ASSIGN. > Encoders. By default, they are assigned to gamma, saturation, detail and ND.
This looks like this on the main screen:
For cine-style cameras like the Venice, it is better to assign them to color temperature, tint and ND.
This looks like this on the main screen: