Sony Venice

Supported Models​

  • Sony Venice 1
  • Sony Venice 2

Protocols and Controls​

There are two protocols:

  • Sony Venice Serial: the typical Sony Venice multicam workflow
  • Sony Venice IP: if you're working in S-Log and don't want/need camera control through the RCP paint mode
ControlVenice IPVenice Serial
Exposure (Iris, Gain, Shutter *1, ND filter *2)✓ *3✓ *4
White balance (color temperature and tint)✓ *5✓ *6
Black balance (R/B and Master)-✓
Advanced shading (Flare, Detail, Matrix, Multi Matrix)-✓ *7
REC (start/stop)✓✓
Other controls (Base ISO *8, APR, pattern, horizontal/vertical flip, replay *9, User Keys *10, TC)✓-
Tally-✓ *11
Lens (zoom, focus) *12✓-
Scene file save/recall✓✓
  1. Shutter can be displayed/controlled as angle or speed. ECS is also available.
  2. ND is presets only.
  3. Venice IP: gain is expressed in ISO and only affects the SDI output. Base ISO (800 or 3200) affects the ISO range and the (fixed) REC ISO.
  4. Venice Serial: gain is expressed in dB, in 3 dB steps.
  5. Color temperature, tint and AWB.
  6. R/B and color temperature are available in Venice Serial, but not tint (only the color temperature is affected).
  7. Detail can be changed and toggled on/off. Matrix and Multi Matrix can be changed and toggled.
  8. Base ISO only in Venice IP.
  9. To replay, switch to Clips under Camera > User Keys > Custom. Then under Record > Replay, you can replay your last clip.
  10. User keys are accessible on the RCP under Camera > User Keys, in User Keys and Custom. You can only call them; they must be assigned on the camera body under Project > Assignable Button.
  11. Venice Serial: RED tally only, and only when not recording (the REC status is used to display the tally).
  12. Venice IP: zoom/focus are controlled in speed (position is display only).

Wiring​

The camera can be controlled in two modes:

  • Sony Venice IP: the camera is controlled over IP (works best for S-Log-based workflows; RCP/paint mode is disabled).
  • Sony Venice Serial: the camera is controlled over the remote (8-pin) port, using the camera's RCP paint mode.

Locally (LAN), you can control the camera with just the RCP for IP, or by adding a CI0 for serial. Wirelessly (4G, RF, Wi-Fi), you can control it using a RIO for both IP and serial (Steadicam, robotics, etc.).

Sony Venice IP (LAN)​

Venice IP over LAN

  • The RCP is powered by PoE or a 12V PSU.
  • The RCP talks directly to the camera over IP.
note

This can work through a simple Ethernet switch or a fiber system such as the Ereca CAM Racer.

Sony Venice Serial (LAN)​

Venice Serial over LAN

  • The RCP is powered by PoE or a 12V PSU.
  • The CI0 or RIO is powered by the camera through the cable (no D-TAP required).
  • Cable: CY-CBL-SONY-8P-03 (controls the camera and powers the CI0/RIO; see the Cable Catalog)
note

This can work through a simple Ethernet switch or a fiber system such as the Ereca CAM Racer.

  • Some people prefer to keep the CI0/RIO on the camera side, so there is simply Ethernet between the RCP and the CI0/RIO.
  • Others prefer to keep the CI0/RIO on the RCP side and carry the serial signal over the Ereca (pro: a clean setup on the camera side; con: you lose the flexibility of the RIO for external motors, lens control, etc.).

Sony Venice IP (Wireless)​

Venice IP wireless

  • The RCP is powered by PoE or a 12V PSU and connected to the internet.
  • The RIO is powered by D-TAP.
  • The RIO is connected to the camera over Ethernet.
  • The RCP talks to the RIO over the internet (using 4G, RF, Wi-Fi, etc.).
note

Video must be transmitted separately over RF; Cyanview only handles the telemetry.

Sony Venice Serial (Wireless)​

Venice Serial wireless

  • The RCP is powered by PoE or a 12V PSU and connected to the internet.
  • The RIO is powered by D-TAP.
  • The RIO is connected to the camera with a CY-CBL-SONY-8P-03 cable.
  • The RCP talks to the RIO over the internet (using 4G, RF, Wi-Fi, etc.).
note

Video must be transmitted separately over RF; Cyanview only handles the telemetry.

Camera Setup​

Venice IP​

  1. Set the IP address and mask under Technical > Network > Setting:
    • Set Setting to LAN
    • In the LAN submenu:
      • Set DHCP to Off
      • Set IP Address to the desired camera IP (e.g. 10.192.10.100)
      • Set Subnet Mask to the desired subnet (e.g. 255.255.0.0)
  2. Set the username and password under Technical > Authentication
  3. Under Technical > Special Configuration, set RM / RCP Paint Con to Off

Venice Serial​

  • Under Technical > Special Configuration, set RM / RCP Paint Con to On

RCP Setup​

Add a new camera in the RCP configuration UI.

Venice IP​

  1. Enter a custom number, name, etc.
  2. Select brand: Sony
  3. Select protocol: Sony Venice(IP)
  4. Enter the camera's IP address
  5. Enter the camera's login/password

Venice IP block

Venice IP setup

Venice Serial​

  1. Enter a custom number, name, etc.
  2. Select brand: Sony
  3. Select protocol: Sony Venice(Serial)
  4. Select the CI0/RIO port the camera is plugged into

Venice Serial block

Venice Serial setup

RCP Operation​

Overview​

RCP main screen

The exposure knob and joystick give access to iris, ISO and shutter.

Assignable Keys​

You can customize the 10 buttons at the top of the RCP main screen under MENU > SYSTEM > ASSIGN. > Set Buttons. By default, keys 1-5 are not assigned (NA). You can assign them to something more useful, for example:

Key assignment example

This gives you quick access to:

  • The Lock button becomes a shortcut to the REC menus (replay, etc.), and its LED reflects the REC status.

    REC menu

  • The camera's assignable buttons (1-4, A-C, Home and Clips)

    Camera assignable buttons 1

    Camera assignable buttons 2

  • Base ISO from the gain view

    Base ISO

  • Shutter angle/speed from the shutter view

    Shutter angle/speed

  • Test patterns from the test view

    Test patterns

Encoders​

You can customize the 4 encoders below the RCP main screen under MENU > SYSTEM > ASSIGN. > Encoders. By default, they are assigned to gamma, saturation, detail and ND.

Default encoder assignment

This looks like this on the main screen:

Main screen with default encoders

For cine-style cameras like the Venice, it is better to assign them to color temperature, tint and ND.

Encoder assignment for cine cameras

This looks like this on the main screen: